Agar Petri dish is the standard lab container of a shallow, lidded dish filled with a seaweed-derived nutrient gel, used to grow and observe bacteria, fungi, and other microbes.
If you work in a biology lab or teach microbiology, you have used one. An agar Petri dish is simply a Petri dish — transparent, round, lidded — that holds a layer of agar gel, which is the food source for microorganisms. The dish provides a sterile, sealed environment, while the agar supplies moisture and nutrients. Together they create a controlled space where colonies can grow visibly, letting you identify, count, or isolate organisms. Getting the right dish and preparing it correctly makes the difference between a clean experiment and a contaminated one.
What Makes Up an Agar Petri Dish?
An agar Petri dish is two things combined: the dish vessel and the agar medium. The dish is a shallow, transparent container made of either glass or plastic, with a slightly larger lid that rests on top without sealing completely. The agar is a jelly-like substance extracted from red seaweed (Gracilaria or Gelidium species) and mixed with nutrients like broth or blood. When poured into the dish and cooled, it solidifies into a stable, moist surface that microbes can grow on.
The German bacteriologist Julius Richard Petri invented the dish in 1887 while working as Robert Koch’s assistant. His design — a covered glass plate — remains essentially unchanged today, though modern versions use disposable polystyrene for convenience.
Why 90 mm Is the Standard Size
The 90 mm diameter dish (roughly 3.5 inches) is the universal standard in labs worldwide. It is large enough to hold a useful amount of agar and plenty of colonies, but small enough to handle easily and store stacked. Other sizes exist for specific jobs: 35 mm and 50 mm dishes are used for small samples or limited media, while 100 mm and 140 mm dishes accommodate larger experiments or multiple sample types on one plate.
The table below shows the common sizes, materials, and typical uses.
| Diameter | Common Material | Typical Use |
|---|---|---|
| 35 mm | Polystyrene (plastic) | Small sample testing, tissue culture |
| 50 mm | Polystyrene (plastic) | Student experiments, single colonies |
| 60 mm | Polystyrene or glass | General microbiology work |
| 90 mm | Polystyrene or borosilicate glass | Standard bacterial culture, antibiotic testing |
| 100 mm | Polystyrene or glass | Larger experiments, multiple samples |
| 140 mm | Polystyrene or glass | Large-format work, environmental sampling |
Disposable plastic dishes are typically gamma-irradiated and ready to use. Glass dishes (borosilicate) can be sterilized and reused many times, though they require careful cleaning and autoclaving between uses.
Vented vs. Non-Vented Lids — Which One Do You Need?
The lid design affects air exchange during incubation. Vented lids have small ridges or gaps that allow oxygen to flow in, making them the right choice for aerobic bacteria — the kind that need oxygen to thrive. Non-vented lids seal more tightly and limit oxygen, which is essential for anaerobic cultures that grow without air. Most classroom and general lab work uses vented lids because the majority of common bacteria are aerobic.
How to Prepare an Agar Plate the Right Way
Making your own agar plates is straightforward if you follow a clean, step-by-step process. Contamination and condensation are the two biggest problems, and both come from rushing or skipping temperature control.
- Mix the media. Combine agar powder with distilled water and nutrients (for example, nutrient broth or LB broth) in an Erlenmeyer flask. Stir until the powder is fully suspended.
- Sterilize. Autoclave the flask at 121°C for 15–20 minutes. The agar must be completely clear before pouring — any cloudiness means it isn’t fully dissolved.
- Cool to 50–60°C. Let the flask sit until it feels warm but not hot to the touch (roughly 50–60°C). Pouring hotter causes excess condensation on the lid, which drips onto the agar and ruins the surface.
- Pour in a sterile area. Work inside a laminar flow hood or near a Bunsen burner flame. Use the “Pacman technique”: lift the lid only at the edge — just enough to pour — so the opening is a tiny slit.
- Add about 25 mL. That fills the dish to the correct depth — about ¼ to ½ inch. Too thin and the agar dries quickly; too thick and condensation pools on the lid.
- Let it solidify. Leave the plates undisturbed for 30–60 minutes. The agar will turn from liquid to a firm gel.
- Store upside-down. Close the lid, wrap with parafilm if needed, and stack the plates upside-down in the refrigerator. Storing upside-down stops condensation from dripping onto the agar surface.
If you are buying pre-poured plates instead of making them, you can find high-quality options in the best agar Petri dishes buyers guide to avoid the preparation steps.
Common Mistakes That Ruin a Good Plate
Even experienced lab workers hit these pitfalls occasionally. Here is what to watch for:
- Pouring media hotter than 60°C. This fills the lid with condensation droplets that drip onto the agar and blur colony boundaries. Cool the flask until you can hold it comfortably.
- Pouring too thin (
- Lifting the lid all the way off. That lets airborne bacteria fall into the dish. Use the Pacman lift — barely open the edge.
- Storing plates right-side up. Condensation pools on the lid and drips down, disrupting the growth surface. Always store upside-down.
- Pouring before the agar is fully dissolved. Cloudy agar sets into a fragile, squishy layer that tears easily under a loop or spreader.
Agar Plate Sizes and Lid Types at a Glance
| Aspect | Vented Lid | Non-Vented Lid |
|---|---|---|
| Air exchange | Allows oxygen flow | Limits oxygen entry |
| Best for | Aerobic bacteria (most lab work) | Anaerobic bacteria |
| Typical use | Classroom, clinical, environmental | Specialized anaerobic chambers |
| Appearance | Small ridges or gaps near edge | Smooth, flush lid surface |
Safety and Disposal
Agar plates grow live microorganisms, so they are biological waste after use. Never throw used plates in the regular trash. Treat them with a 10% bleach solution or autoclave them to kill the cultures before disposal. Wear gloves when handling samples, work near a flame or hood to keep airborne contaminants out, and seal plates with parafilm or tape once inoculated to prevent leaks.
The Merriam-Webster definition of a Petri dish confirms the basic vessel, but the real utility comes from pairing it with the right agar and preparation method. Stick with the 90 mm standard for most jobs, choose vented lids for aerobic work, and never skip the cool-down step before pouring.
FAQs
Is an agar Petri dish the same thing as a Petri dish?
Not exactly. A Petri dish is just the empty glass or plastic container. An agar Petri dish is the dish filled with the nutrient gel, ready for culture work. People often use the terms interchangeably in conversation, but the difference matters when ordering supplies.
Can I reuse a plastic agar dish?
Most plastic Petri dishes are designed for single use. Polystyrene dishes warp or degrade during sterilization, so reusing them risks contamination and poor seal fit. Glass dishes are reusable — they go through an autoclave cycle and can be used dozens of times if handled carefully.
How long do poured agar plates last in the fridge?
Properly sealed and stored upside-down at 4°C, agar plates stay usable for 2 to 4 weeks. After that, the agar starts to dry out, and contaminants may appear even in sealed plates. Always check for cracks, discoloration, or visible colonies before using stored plates.
Why does my agar always turn out too wet?
Excess moisture usually means the media was poured too hot. Let it cool to 50–60°C, and you will see far less condensation. Pouring the agar too deep (over half the dish height) also traps extra moisture. Stick to roughly 25 mL for a standard 90 mm plate.
References & Sources
- Merriam-Webster. “Petri Dish Definition.” Defines the basic vessel.
- ConductScience. “How to Make Agar Plates.” Step-by-step pouring protocol with temperature and aseptic technique.
- Microbe Online. “Petri Dish, Types, Uses, and Automated Petri Dish Filler.” Covers 90 mm standard size and 1887 invention date.
- Utah Teach Genetics. “Pouring Agar Plates.” Details the 25 mL volume and dissolution requirements.
- Sigma-Aldrich. “Petri Dishes.” Polystyrene, gamma-irradiated, and tissue culture surface options.