The precise way to test a 20 amp fuse is with a multimeter set to continuity: a beep confirms the fuse is intact and working.
For the full breakdown, see our best 20 Amp Fuses guide.
You can’t always tell if a 20 amp fuse is blown just by looking at it.
The 20 amp rating tells you the capacity of the fuse, but the multimeter only checks if the internal link is broken or still intact.
The Right Way to Set Up the Test
This removes any chance of a ghost reading from a parallel circuit path.
- Grab your multimeter. Plug the black lead into the Common (COM) jack and the red lead into the Ohms (Ω) jack.
- Set the dial. Choose continuity mode, usually marked by a sound wave symbol. This makes the meter beep when it finds a complete path.
- Check your gear. Touch the metal probe tips together. A solid beep confirms your multimeter and leads are working correctly.
- Touch the fuse ends. Touch one probe to each metal cap or blade of the 20 amp fuse. Probe polarity does not matter.
- Read the result. A steady beep or a reading near 0 Ohms means the fuse is good. Silence, or a reading showing O.L. (Open Line), means the fuse is blown.
How to Interpret the Results
If you get a beep when the fuse is installed but silence when you pull it out, you were reading through another component in the circuit—always test out of the holder for a reliable answer. If you only have a resistance setting, set it to the lowest range (usually 200 Ohms). , while a blown fuse shows O.L. or an unreasonably high number.
| Multimeter Reading | Fuse Condition | Action Needed |
|---|---|---|
| Steady beep / ~0 Ω | Good | Reinstall and troubleshoot the device |
| No beep / O.L. | Blown | Replace with an identical 20A fuse |
| Beep installed, no beep out | False reading | Test the fuse outside the holder |
When the Fuse Is Blown
Once your multimeter confirms the fuse is open, don’t guess at the replacement. You need an exact 20 amp match.
FAQs
Do you need to disconnect the battery to test a 20 amp fuse?
What if my multimeter doesn’t have a continuity setting?
Use Resistance (Ohms) mode instead. Set it to the lowest number (like 200). A bad one will read OL or 1. This is just as accurate, but you have to look at the screen instead of listening for a beep.
Does the test change for a 20 amp fuse vs. a 10 amp fuse?
No. The multimeter checks for continuity along the conductive path, which is the same process regardless of the fuse’s amperage rating.
References & Sources
- Fluke. “How to Check a Fuse with a Multimeter.” Explains the standard continuity method for testing all fuse types.
- Swe-Check. “Fuse Testing Guide.” Details visual and electrical inspection for automotive and household fuses.